Vicom OTDR Selection Guide

List 7: All Singlemode, Tri-Wave, Single & Dual Port, 1310/1550 & 1625 or 1650nm Models

contact_us_small.jpg

NOTE: Approx Distance” below refers to the approximate fibre distance that can accurately be certified based on 0.2dB/km fibre loss @ 1550nm (0.22dB for 1625/1650 only OTDRs) & 0.1dB splices every 2km. Note too that for the same distance, test times reduce with dynamic range increase – roughly half the test time for every 2-3dB increase in dynamic range.

Measurement Range (range of accurate measurement) is approx 8 dB less than Dynamic Range (range to find end-of-fibre)

 

VIAVI logo

MTS-4000 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM4000HVT & E4126MP2-PC 1 SM 1310/1550/1625 46/45/44 150-180 

 

VIAVI logo

MTS-2000 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM2000HVT & E4126MP2-PC 1 SM 1310/1550/1625 46/45/44 150-180 

 

VIAVI logo

SmartOTDR Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

E138FA65-PC

1

2

SM

SM

1310/1550

filtered 1650

37/35

32

110-140

90-120

E138FA65-APC

1

2

SM

SM

1310/1550

filtered 1650

37/35

32

110-140

90-120

E136FB-PC

1

2

SM

SM

1310/1550

filtered 1625

40/40

41

130-160

120-150

E136FB-APC

1

2

SM

SM

1310/1550

filtered 1625

40/40

41

130-160

120-150

 

VIAVI logo

MTS-5800 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM5800HVT & E4126MP2-PC 1 SM 1310/1550/1625 46/45/44 150-180 

 

Shineway Technologies logo

MTP-200X Series

Optical Options

 (Not applicable to each model variant, click below for full details of each model)

Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe

Model Port # Mode Wavelength Dynamic Approx Distance
(Click for Details)       Range (see note above) 
      (nm) (dB) (km)
MTP-200X-31VCPL 1  SM 1310/1550 42/41 130-160
  2  SM filtered 1625 40 130-160
MTP-200X-33VC 1 SM 1310/1550/1650 42/40/39 130-160

 

Shineway Technologies logo

palmOTDR SERIES

Optical Options (Not applicable to each model variant, click below for full details of each model)

Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe

Model Port # Mode Wavelength Dynamic Approx Distance
(Click for Details)       Range (see note above) 
      (nm) (dB) (km)
palmOTDR-S20C/X 1 SM 1310/1550 38/37 120-150
  2 SM  filtered 1625 or 1650  37 110-140
palmOTDR-P31C 1 SM 1310/1550  38/37  120-150
  2 SM filtered 1625 37 110-140