Vicom OTDR Selection GuideList 6: All Singlemode, Tri-Wave, 1310/1550 and 1625 or 1650nm Models |
NOTE: “Approx Distance” below refers to the approximate fibre distance that can accurately be certified based on 0.2dB/km fibre loss @ 1550nm (0.22dB for 1625/1650 only OTDRs) & 0.1dB splices every 2km. Note too that for the same distance, test times reduce with dynamic range increase – roughly half the test time for every 2-3dB increase in dynamic range.
Measurement Range (range of accurate measurement) is approx 8 dB less than Dynamic Range (range to find end-of-fibre)
MTS-4000 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
No applicable models are available in this configuration |
MTS-2000 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
No applicable models are available in this configuration |
SmartOTDR Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
E138FA65-PC |
1 2 |
SM SM |
1310/1550 filtered 1650 |
37/35 32 |
110-140 90-120 |
E138FA65-APC |
1 2 |
SM SM |
1310/1550 filtered 1650 |
37/35 32 |
110-140 90-120 |
E136FB-PC |
1 2 |
SM SM |
1310/1550 filtered 1625 |
40/40 41 |
130-160 120-150 |
E136FB-APC |
1 2 |
SM SM |
1310/1550 filtered 1625 |
40/40 41 |
130-160 120-150 |
MTS-5800 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
No applicable models are available in this configuration |
MTP-200 Series |
Optical Options
(Not applicable to each model variant, click below for full details of each model)
Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe
Model | Port # | Mode | Wavelength | Dynamic | Approx Distance |
(Click for Details) | Range | (see note above) | |||
(nm) | (dB) | (km) | |||
MTP-200C-31VCPL | 1 | SM | 1310/1550 | 42/41 | 130-160 |
2 | SM | filtered 1625 | 40 | 120-150 |
palmOTDR SERIES |
Optical Options (Not applicable to each model variant, click below for full details of each model)
Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe
Model | Port # | Mode | Wavelength | Dynamic | Approx Distance |
(Click for Details) | Range | (see note above) | |||
(nm) | (dB) | (km) | |||
palmOTDR-S20C/X | 1 | SM | 1310/1550 | 38/37 | 120-150 |
2 | SM | filtered 1625 or 1650 | 37 | 110-140 | |
palmOTDR-P31C | 1 | SM | 1310/1550 | 38/37 | 110-140 |
2 | SM | filtered 1625 | 37 | 90-110 |