Vicom OTDR Selection Guide

List 4: All Singlemode, Dual Wavelength, 1310/1550nm Models

contact_us_small.jpg

NOTE: Approx Distance” below refers to the approximate fibre distance that can accurately be certified based on 0.2dB/km fibre loss @ 1550nm (0.22dB for 1625/1650 only OTDRs) & 0.1dB splices every 2km. Note too that for the same distance, test times reduce with dynamic range increase – roughly half the test time for every 2-3dB increase in dynamic range.

Measurement Range (range of accurate measurement) is approx 8 dB less than Dynamic Range (range to find end-of-fibre)

 

VIAVI logo

MTS-4000 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM4000HVT & E4126LA 1  SM 1310/1550 35/33 100-130 
EM4000HVT & E4126MA2-PC 1 SM 1310/1550 40/40 130-160 
EM4000HVT & E4126MA3-APC 1 SM 1310/1550 43/41 130-160 

 

VIAVI logo

MTS-2000 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM2000HVT & E4126LA 1  SM 1310/1550 35/33 100-130 
EM2000HVT & E4126MA2-PC 1 SM 1310/1550 40/40 130-160 
EM2000HVT & E4126MA3-APC 1 SM 1310/1550 43/41 130-160 

 

VIAVI logo

SmartOTDR Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

E126A-PC 1 SM 1310/1550 37/35 110-140 
E126A-APC 1  SM 1310/1550 37/35 110-140 
E126B-PC 1 SM 1310/1550 40/40 130-160 
E126B-APC 1 SM 1310/1550 40/40 130-160 

 

VIAVI logo

MTS-5800 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM5800HVT & E4126LA 1  SM 1310/1550 35/33 100-130 
EM5800HVT & E4126MA2-PC 1 SM 1310/1550 40/40 130-160 
EM5800HVT & E4126MA3-APC 1 SM 1310/1550 43/41 130-160 

 

anritsu-logo.jpg

MTP-200X SERIES

Optical Options (Not applicable to each model variant, click below for full details of each model)

Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe

Model Port # Mode Wavelength Dynamic Approx Distance
(Click for Details)       Range  
      (nm) (dB) (km)
MTP-200X-20VC 1 SM 1310/1550 38/37 110-130
MTP-200X-20VD 1 SM 1310/1550 45/43 130-150
MTP-200X-20VF 1 SM 1310/1550 50/48 140-160

 

palmOTDR SERIES

Optical Options (Not applicable to each model variant, click below for full details of each model)

Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe

Model Port # Mode Wavelength Dynamic Approx Distance
(Click for Details)       Range  
      (nm) (dB) (km)
palmOTDR-S20AE 1 SM 1310/1550 32/30 90-120
palmOTDR-S20BE 1 SM 1310/1550 35/34 110-140
palmOTDR-S20C/N  1  SM 1310/1550 40/38 120-150
palmOTDR-S20D/N 1 SM 1310/1550 45/43 140-170
palmOTDR-S20F 1 SM 1310/1550 50/48 160-190