NOTE: Approx Distance” below refers to the approximate fibre distance that can accurately be certified based on 0.2dB/km fibre loss @ 1550nm (0.22dB for 1625/1650 only OTDRs) & 0.1dB splices every 2km. Note too that for the same distance, test times reduce with dynamic range increase – roughly half the test time for every 2-3dB increase in dynamic range.

Measurement Range (range of accurate measurement) is approx 8 dB less than Dynamic Range (range to find end-of-fibre)

VIAVI logo

MTS-4000 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM4000HVT & E4123MM 1 MM 850/1300 26/24  
EM4000HVT & E4146QUAD

1

2

SM

MM

1310/1550

850/1300

37/35

26/24

110-140

 

 

VIAVI logo

MTS-2000 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM2000HVT & E4123MM 1 MM 850/1300 26/24  
EM2000HVT & E4146QUAD

1

2

SM

MM

1310/1550

850/1300

37/35

26/24

110-140

 

 

VIAVI logo

SmartOTDR Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

No applicable models are available in this configuration

 

VIAVI logo

MTS-5800 Platform / E4100 OTDR Module Series

Optical Options

Visual Fault Locator; Optical Power Meter; Video Inspection Probe

Model

click for details

 

Port #

 

 

Mode

 

 

Wavelength

 

(nm)

Dynamic Range

 

(dB) 

Approx Distance

see note above

(km)

EM5800HVT & E4123MM 1 MM 850/1300 26/24  
EM5800HVT & E4146QUAD

1

2

SM

MM

1310/1550

850/1300

37/35

26/24

110-140

 

 

Shineway Technologies logo

MTP-200X Series

Optical Options

 (Not applicable to each model variant, click below for full details of each model)

Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe

Model Port # Mode Wavelength Dynamic Approx Distance
(Click for Details)       Range (see note above) 
      (nm) (dB) (km)
MTP-200X-40VC 1 SM 1310/1550 38/36  110-140
  2 MM 850/1300 23/36  

 

Shineway Technologies logo

palmOTDR SERIES

Optical Options (Not applicable to each model variant, click below for full details of each model)

Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe

Model Port # Mode Wavelength Dynamic Approx Distance
(Click for Details)       Range (see note above) 
      (nm) (dB) (km)
palmOTDR-M20AE 1 MM 850/1300 21/24  
palmOTDR-Q40A   1   SM 1310/1550  32/30 90-120 
  2  MM 850/1300  21/24