Vicom OTDR Selection GuideList 9: All Singlemode, Quad-wave, 1310/1490/1550/1625 Models |
NOTE: “Approx Distance” below refers to the approximate fibre distance that can accurately be certified based on 0.2dB/km fibre loss @ 1550nm (0.22dB for 1625/1650 only OTDRs) & 0.1dB splices every 2km. Note too that for the same distance, test times reduce with dynamic range increase – roughly half the test time for every 2-3dB increase in dynamic range.
Measurement Range (range of accurate measurement) is approx 8 dB less than Dynamic Range (range to find end-of-fibre)
MTS-4000 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
No applicable models available in this configuration |
MTS-2000 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
No applicable models available in this configuration |
SmartOTDR Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
No applicable models are available in this configuration |
MTS-5800 Platform / E4100 OTDR Module Series |
Optical Options
Visual Fault Locator; Optical Power Meter; Video Inspection Probe
Model click for details
|
Port #
|
Mode
|
Wavelength
(nm) |
Dynamic Range
(dB) |
Approx Distance see note above (km) |
No applicable models available in this configuration |
MTP-200 Series |
Optical Options
(Not applicable to each model variant, click below for full details of each model)
Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe
Model | Port # | Mode | Wavelength | Dynamic | Approx Distance |
(Click for Details) | Range | (see note above) | |||
(nm) | (dB) | (km) | |||
No applicable models available in this configuration |
palmOTDR SERIES |
Optical Options (Not applicable to each model variant, click below for full details of each model)
Visual Fault Locator/Visible Laser Diode; Optical Power Meter; Laser Source; Video Inspection Probe
Model | Port # | Mode | Wavelength | Dynamic | Approx Distance |
(Click for Details) | Range | (see note above) | |||
(nm) | (dB) | (km) | |||
No applicable models available in this configuration |